- Home
- ยป
- Our Products
- »
- DYNE TEST PEN
DYNE TEST PEN
Providing you the best range of mapple corona dyne test pen (imported) with effective & timely delivery.
Mapple Corona Dyne Test Pen (Imported)
Product Price: Rs 680 / PieceGet Best Price
Minimum Order Quantity: 1 Piece
Product Brochure
Product Details:
Color | Pink |
Material | Plastic |
Frequency | 100's of tests from each marker |
Usage/Application | Industirlal, Automotive,Aerospace, Packaging, Medical Device |
Brand | MAPPLE |
Dyne Value | 30 to 72 |
Length | 14 MM |
Product Type | Corona / Wettability Test Dyne Test Pen |
Srandard | UNITED STATES |
Storage Temperature | <25 Degree C |
Shelf Life | 5 to 6 months |
Peripheral Shrinkage | 4 sec |
Remove the pen cap and briefly depress the tip on a clean surface until moist:
- Apply the mark over a test area of approximately 2 inch long
- Note the required time for the applied marking to break into droplets and/or peripheral shrinkage to occur
- Read the solution behavior by observing the center area of the applied mark
- If the dyne solution does not break into droplets and/or peripheral shrinkage after 4 seconds repeat the test with the next higher surface tension solution
- If the solution breaks into droplets and /or peripheral shrinkage in less than 4 seconds, repeat test with next lower surface tension solution
- Do not repeat test on the same area of material
- Repeat Steps 1 and 2 until the correct dyne level is determined
- The correct dyne level will be equal to the solution that holds for exactly 4 seconds before droplets or peripheral shrinkage occur
- As a general guideline surface coverage tension should be approximately 10 dynes higher than ink, adhesive or coating
- This may not be the case for every application
Dyne Test Pen
General Guidelines:
- Use of repetitive marking will result in a false reading
- Dyne Pens typically have a 6-12 month shelf life
- Each pen is rated for the minimum dyne level that the ink will determine
- Surface energy testing should be conducted immediately after treatment (Air plasma, flame plasma, chemical plasma, RF gas)
- Treated surfaces are time sensitive and are affected by environmental conditions
- Such as temperature and humidity
- Do not touch or contaminate the surface to be tested
- Dirty surfaces lose their wettability; therefore clean test level area
- Do not use contaminated or outdated pens
- Store and use pens at room temperature
- The Pen should not be exposed to direct light
- Therefore keep them closed when not in use
- Also repeated ink exposure to air will alter the dyne levels
- Properly sealed pens prevent this from occurring
- Inconsistent or excessive pressure may provide a false dyne level reading
Corona Dyne Test Pen (Imported)
Additional Information:
- Production Capacity: As Per Order
- Delivery Time: 2-3 days
Yes! I am InterestedRequest A Callback