Call 08046031650 81% Response Rate

Send Email

DYNE TEST PEN

Providing you the best range of mapple corona dyne test pen (imported) with effective & timely delivery.

Mapple Corona Dyne Test Pen (Imported)

Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
  • Mapple Corona Dyne Test Pen (Imported)
Get Best Quote
Product Price: Rs 680 / PieceGet Best Price

Minimum Order Quantity: 1 Piece

Product Brochure

Product Details:
ColorPink
MaterialPlastic
Frequency100's of tests from each marker
Usage/ApplicationIndustirlal, Automotive,Aerospace, Packaging, Medical Device
BrandMAPPLE
Dyne Value30 to 72
Length14 MM
Product TypeCorona / Wettability Test Dyne Test Pen
SrandardUNITED STATES
Storage Temperature<25 Degree C
Shelf Life5 to 6 months
Peripheral Shrinkage4 sec
We are a well-renowned organization in the industry to provide our patrons the best quality array of Dyne Test Pen.

Remove the pen cap and briefly depress the tip on a clean surface until moist:
  • Apply the mark over a test area of approximately 2 inch long
  • Note the required time for the applied marking to break into droplets and/or peripheral shrinkage to occur
  • Read the solution behavior by observing the center area of the applied mark
  • If the dyne solution does not break into droplets and/or peripheral shrinkage after 4 seconds repeat the test with the next higher surface tension solution
  • If the solution breaks into droplets and /or peripheral shrinkage in less than 4 seconds, repeat test with next lower surface tension solution
  • Do not repeat test on the same area of material
  • Repeat Steps 1 and 2 until the correct dyne level is determined
  • The correct dyne level will be equal to the solution that holds for exactly 4 seconds before droplets or peripheral shrinkage occur
  • As a general guideline surface coverage tension should be approximately 10 dynes higher than ink, adhesive or coating
  • This may not be the case for every application

Dyne Test Pen

General Guidelines:

  • Use of repetitive marking will result in a false reading
  • Dyne Pens typically have a 6-12 month shelf life
  • Each pen is rated for the minimum dyne level that the ink will determine
  • Surface energy testing should be conducted immediately after treatment (Air plasma, flame plasma, chemical plasma, RF gas)
  • Treated surfaces are time sensitive and are affected by environmental conditions
  • Such as temperature and humidity
  • Do not touch or contaminate the surface to be tested
  • Dirty surfaces lose their wettability; therefore clean test level area
  • Do not use contaminated or outdated pens
  • Store and use pens at room temperature
  • The Pen should not be exposed to direct light
  • Therefore keep them closed when not in use
  • Also repeated ink exposure to air will alter the dyne levels
  • Properly sealed pens prevent this from occurring
  • Inconsistent or excessive pressure may provide a false dyne level reading
38 dyne test pencorona dyne test pen, dyne pen price, dyne pen test, test pens dyne, dyne test pen, dyne test pen india, dyne test pen set, dyne test pens, dyne testing pen, mapple dyne test pen

Corona Dyne Test Pen (Imported)



Additional Information:

  • Production Capacity: As Per Order
  • Delivery Time: 2-3 days
Yes! I am InterestedRequest A Callback

EXPLORE MORE CATEGORIES

© Octagon Solutions. All Rights Reserved (Terms of Use)Developed and managed by IndiaMART InterMESH Ltd.